Front Panel Functions; Using The Front Panel To Monitor Unit Status And Unit Operating Data; Figure 5-11. Front Panel Display With Status And Generator Leds - Advanced Energy Paramount MF 2 kW User Manual

Generator
Table of Contents

Advertisement

®
Advanced Energy
front panel if you scroll to the External Volts generator LED. You can also read peak
to peak voltage on the Sense V-In connector with host port command 168.
• Minimum voltage set point in this mode = 0.1 V
• Maximum forward power in the external voltage regulation mode = 1800 W
The external voltage scaling may be changed using host command 9, set maximum
external feedback value, when using a fixed match other than the AE Low Frequency
Fixed Match. The user can also limit the usable range of the bias voltage by using
host command 6, set user external feedback limit.
The output voltage at the Bias V-Out SMA connector is proportional to the input
voltage of the Sense V-In connector. 0 V input voltage at the Sense V-In connector
gives 0 V output at the Bias V-Out connector. 10 V input voltage gives -5 V output.
If input voltage is pulsing (with pulsing RF), output voltage is constant (DC).

FRONT PANEL FUNCTIONS

Using the Front Panel to Monitor Unit Status and Unit
Operating Data
Figure 5‑11. Front panel display with Status and Generator LEDs
The Paramount MF 2 kW generator does not provide an operator control panel. All
power, control, and water connections are made at the rear of the unit. Six Status
LEDs are visible from the front of the unit for monitoring the status of the generator.
You can also monitor basic operating data on the front panel of your unit using the
seven segment, 4-digit numeric display and the Generator LEDs. To change the
display, push the Display Select button below the numeric display. Push the Display
Select button multiple times to scroll through the Generator LED list. When a
particular Generator LED is lit, the display screen will show the current operating
data for that parameter.
57020114-00E
Installation, Setup, and Operation
®
Paramount
MF 2 kW Generator
5‑16

Advertisement