Advanced Energy Paramount MF 2 kW User Manual page 55

Generator
Table of Contents

Advertisement

®
Advanced Energy
Table 4‑10. AE Host commands (Continued)
Command
14
set active control
mode
26
set pulsing
configuration
57020114-00E
Description
maximum external feedback value while the
output is on.
Valid values are from 10 V to 65535 V. If the
new maximum external feedback value is less
than the user external feedback limit, the unit
reduces the user external feedback limit to
equal to the new maximum external feedback
value.
Send 3 data bytes:
• Bytes 0 and 1 = Maximum external
feedback value in volts
• Byte 2 = Dummy byte for RFX II
compatibility (can contain any value)
Sets the control mode. This mode cannot be
changed while the output is on.
Send 1 data byte (8-bit value):
• 2 = Host
• 4 = User port (analog)
• 8 = Diagnostic
Command 155 reports this value.
Set pulsing configuration. Set unit as master
or slave, turn pulse sync input on or off, set
memory mode, set explicit enable mode, and
enable or disable pulsing mode.
This command allows you to send
subcommands. Send a value in the first two
bytes that selects the parameter to set, and
then send subcommands to set parameter
values.
Byte 0-1 =
1
Set pulsing mode
2
Set pulse sync output
3
Reserved
4
Reserved
5
Set memory mode
Communication Controls
Paramount
Subcommand
®
MF 2 kW Generator
Data Bytes
Data
Sent
Bytes
Returned
1
1
6
1
4‑23