Advanced Energy
Table 4‑10. AE Host commands (Continued)
Command
164
report setpoint and
regulation mode
57020114-00E
Description
◦ Bits 4 through 6 = Reserved
◦ Bit 7 = Interlock (0 = interlock closed,
1 = interlock open)
• Byte 2:
◦ Bits 0 and 1 = Reserved
◦ Bit 2 = High AC line voltage warning
(1 = Warning)
◦ Bit 3 = Reserved
◦ Bit 4 = Low AC line voltage warning
(1 = Warning)
◦ Bit 5 = Protection Limit (1 = Limit
active)
◦ Bits 6 and 7 = Reserved
• Byte 3:
◦ Bit 0 = Reserved
◦ Bit 1 = Inverter not ready (1 = Not
ready)
◦ Bit 2 = Reserved
◦ Bits 3 and 4 = Reserved
◦ Bit 5 = Fault present (0 = No faults, 1
= Faults exist)
◦ Bit 6 = Warning present (0 = No
warnings, 1 = Warnings exist)
◦ Bit 7 = Reserved
When either of the fault present or warning
present bits are set, one or more active or
latched faults or warnings currently exist in
the unit. You can obtain a list of current faults
or warnings by issuing command 223 with
the appropriate parameter.
Reports the output setpoint set with command
8 and the output regulation mode set with
command 3. Reports the setpoint value in
watts when operating in forward or delivered
power regulation modes. If the unit is in DC
bias regulation mode, the setpoint is returned
Communication Controls
®
Paramount
MF 2 kW Generator
Data Bytes
Sent
Returned
0
Data
Bytes
3
4‑49