Table 4‑10. AE Host commands (Continued)
Command
228
report coldplate
temperature
231
report unit serial or
part number
244
report diagnostic
status
57020114-00E
Description
Reports the coldplate temperature in degrees
Celsius. You can send either 0 or 1 data bytes.
If you send 0 data bytes, the unit reports the
coldplate temperature in degrees Celsius.
If you send 1 data byte, the unit reports the
coldplate temperature in tenths of degrees
Celsius.
Send 1 data byte:
• 0 = Coldplate temperature
• 1 = Reserved
Returns 2 data bytes representing the
requested data.
If you send 0 data bytes, reports the unit serial
number; if you send 1 data byte, you can
request either the unit serial number or the
unit part number.
Send 0 data bytes:
• Returns 4 data bytes (32-bit value)
representing the unit serial number.
Send 1 data byte:
• Byte 0 = Value to be returned.
◦ 0 = Requests unit serial number
◦ 1 = Requests unit part number
Returns as many as 12 ASCII characters
representing the unit part number (315 ...) or
the unit serial number.
Reports the results of the diagnostic self test.
Send 1 data byte.
• Byte 0 (8-bit value)
◦ 1 = Report diagnostic status
For the diagnostic status report, returns 5 data
bytes.
• Byte 0 = Status code
Communication Controls
®
Paramount
MF 2 kW Generator
Data Bytes
Sent
Returned
0 or 1
0 or 1
4, or as
many as 12
1
Data
Bytes
2
5
4‑58