Advanced Energy Paramount MF 2 kW User Manual page 61

Generator
Table of Contents

Advertisement

®
Advanced Energy
Table 4‑10. AE Host commands (Continued)
Command
48
set fixed or sweep
frequency mode
58
set retuning
threshold
57020114-00E
Description
Send 4 data bytes to set the value in kHz, or 5
data bytes to set the value in either kHz or Hz.
Send 4 data bytes:
• Frequency in kHz
Send 5 data bytes:
• Byte 0 = kHz or Hz
◦ 0 = Frequency is in kHz
◦ 1 = Frequency is in Hz
• Bytes 1 through 4 = Frequency value
Command 146 reports this value.
Sets the frequency control mode. You can
change this mode while the output is on.
While the output is on, changing to fixed
frequency mode causes the unit to change
immediately to the previously set fixed
frequency. Changing to sweep frequency
mode causes the unit to output the start
frequency first, and then to begin sweeping
according to the tuning algorithm.
The default setting is sweep frequency mode.
The unit stores this value in nonvolatile
memory.
Send 1 data byte (8-bit value):
• 0 = Fixed frequency mode
• 1 = Sweep frequency mode
Command 148 reports this value.
Sets the tuning criteria level at which the
tuning algorithm determines that the generator
requires retuning. The unit stores this
parameter in nonvolatile memory. You cannot
change this setting while output is on. Valid
values are from 1 to 3000.
Send 4 data bytes (32-bit value).
Command 158 reports this value.
Communication Controls
®
Paramount
MF 2 kW Generator
Data Bytes
Sent
Returned
1
4
Data
Bytes
1
1
4‑29

Advertisement

Table of Contents
loading

Table of Contents