Advanced Energy
Table 4‑10. AE Host commands (Continued)
Command
118
set operating
parameter
subcommands
57020114-00E
Description
You can set the memory mode (volatile or
nonvolatile memory) with command 26.
If the unit is a master unit, setting the pulsing
duty cycle to 0 disables pulsing. If the master
unit is operating in volatile storage mode, the
unit always starts operation with pulsing
disabled.
You must enter a valid command for pulsing
frequency and duty cycle to enable pulsing
The default value is 0. Any combination of
pulsing frequency and duty cycle that results
in an output on time less than 225 μs is
invalid and returns a CSR error code.
Valid values range from 10% to 90% and
represent output on time. Setting this value to
0 disables pulsing.
This command is valid only when operating in
master mode. When operating in slave mode,
this command returns CSR 12, Feature Not
Available.
Send 2 data bytes = Duty cycle in %
Command 196 reports this value.
This command allows you to send
subcommands that set a variety of operating
parameters. Send a value in the first two bytes
that selects the parameter to set, and then send
subcommands to set parameter values.
Your unit may not have all the features in this
list. If you issue a command for a feature that
your unit does not have, the unit returns CSR
12, Feature Not Available.
Byte 0 =
1
Set frequency step
minimum
2
Set frequency step
maximum
3
Set step up gain
4
Set step down gain
Communication Controls
Paramount
Subcommand
®
MF 2 kW Generator
Data Bytes
Data
Sent
Bytes
Returned
Variable
1
4‑33