Table 3‑2. Electrical specifications (Continued)
Description
Reflected power limit
Delivered power into
mismatched loads
(Automatic load
mismatch protection,
unlimited load impedance
range, full frequency
range)
Delivered power setpoint
range
Frequency resolution
Regulation modes
selected by tool interface
Measured power accuracy
in full frequency range
and across full line
voltage range
Measured power accuracy
into 50 Ω non-reactive
load
Measured power accuracy
into 2:1 VSWR circle
57020114-00E
1500 W maximum
Generator maximum delivered power is based on reflected power
limit.
• Within VSWR 1.1:1 it is 2000 W
• Within VSWR 2.0:1 it is 2000 W
• Within VSWR 4.79:1 it is 2000 W
• Outside VSWR 4.79:1, maximum delivered power is restricted
by reflected power limit, 1500 W.
5 W to 2000 W
1 Hz
Regulation modes:
• Forward power regulation mode
• Load power regulation mode
• Voltage regulation mode
Measured power accuracy is a combination of the generator and
measurement equipment accuracy.
These specifications were created per an AE test measurement
procedure. Using alternate test measurement devices and/or
procedures will result in deviations from the provided numbers and
values listed in this specification.
Power accuracy:
• ± 0.5 W of setpoint for 5 W to 50 W
• ± 1% of setpoint or ± 2 W, whichever is greater, when
operating at 400 kHz, into a 50 Ω, non-reactive load for 50 W
to 2000 W
• ± 1.5% of setpoint or ± 2 W, whichever is greater, over entire
frequency range when operated into a 50 Ω, non-reactive load,
for 50 W to 2000 W
Power accuracy:
• ± 1.5 W of setpoint for 5 W to 50 W, over entire frequency
range
• ± 2.5% of setpoint or ± 2 W for 50 W to 2000 W, whichever is
greater, over entire frequency range
Specifications
®
Paramount
MF 2 kW Generator
Specification
3‑4