Advanced Energy Paramount MF 2 kW User Manual page 57

Generator
Table of Contents

Advertisement

®
Advanced Energy
Table 4‑10. AE Host commands (Continued)
Command
31
set setpoint ramping
configuration
57020114-00E
Description
Send 6 data bytes.
• Bytes 0 and 1 = 5 (set memory mode)
• Bytes 2 and 3 = Memory mode
◦ 0 = RAM
◦ 1 = NVRAM
• Bytes 4 and 5 = Reserved
Command 172 B0 = 5 reports these values.
Sets the setpoint ramping mode and ramp
parameters or sets ramping memory mode.
The ramp up and down parameters can be set
independently.
Send 6 or 8 data bytes. Sending 6 data bytes
allows you to set the setpoint ramping mode
and ramp parameters. Sending 8 data bytes
allows you to select a subcommand, and then
set the setpoint ramping mode and parameters
or set the ramping memory mode.
Ramping Mode and Parameters
In W/s mode, the ramp parameters represent
the ramp rate in watts per second. The
acceptable range for the ramp up and ramp
down parameters in W/s mode is 1 W/s to
65535 W/s.
In timed mode, the ramp parameters represent
the time in ms. The acceptable range for the
ramp up and ramp down parameters in timed
mode is 1 ms to 65535 ms.
The setpoint ramp parameters can be set while
output is on. The ramp parameters are not
allowed to change during a setpoint ramp that
is currently in progress. The setpoint will not
be ramped in either mode if the setpoint
change is less than 1 W.
6 Data Byte Version
Send 6 data bytes (three 16-bit values):
• Bytes 0 and 1 = Ramp mode
Communication Controls
®
Paramount
MF 2 kW Generator
Data Bytes
Sent
Returned
6 or 8
Data
Bytes
1
4‑25

Advertisement

Table of Contents
loading

Table of Contents