Table 4-3. 25-Pin User Port Pin Descriptions - Advanced Energy Paramount MF 2 kW User Manual

Generator
Table of Contents

Advertisement

®
Advanced Energy
Table 4‑2. User port signal descriptions (Continued)
Description
Analog outputs (AO)
Table 4‑3. 25-pin User port pin descriptions
Signal
Related
Pin
Pin
1
14
2
15
3
16
4
17
57020114-00E
Return wire should be connected to system ground.
Accuracy of voltage measurement: ± 0.6% or ± 20 mV.
The input impedance for all analog input signals is greater than
10 kΩ.
Voltage range 0 V to 10 V
Return wire should be connected to system ground.
Accuracy of voltage measurement: ± 0.6% or ± 15 mV.
The load impedance for all analog output signals should be
greater than 1 kΩ.
Name
Signal
Type
SET POINT
Digital
STATUS
output
RETURN
RFL PWR
Analog
MONITOR
output
FWD/LOAD
Analog
PWR MONITOR
output
RF PWR ON
Digital
input
Communication Controls
®
Paramount
MF 2 kW Generator
Specification
Description
See pin 14.
This signal provides a linearly scaled
readback of reflected power.
• 0 V = 0 W
• 10 V = 1500 W
See
Figure 4‑2
on page 4‑6 for the
wiring diagram.
This signal provides a linearly scaled
readback of forward power when the
generator is operated in forward power
regulation mode or the load power when
operated in load power regulation mode.
In voltage control mode, this signal
provides readback of forward power.
• 0 V = 0 W
• 10 V = Maximum rated output
power
See
Figure 4‑3
on page 4‑7 for the
wiring diagram.
When logic high is applied to this pin,
RF output is enabled (if generator is in
user control mode). Logic low disables
4‑3

Advertisement

Table of Contents
loading

Table of Contents