Table 4‑10. AE Host commands (Continued)
Command
225
report impedance
57020114-00E
Description
Returns 28 data bytes:
• Bytes 0 and 1 (16-bit value) = Forward
power in watts (see command 165).
• Bytes 2 and 3 (16-bit value) = Reflected
power in watts (see command 166).
• Bytes 4 and 5 (16-bit value) = Delivered
power in watts (see command 167).
• Bytes 6 and 7 (16-bit value) = Power
setpoint in watts (see command 8).
• Bytes 8 through 11 (32-bit value) = Real
impedance in hundredths of ohms (see
command 225)
• Bytes 12 through 15 (32-bit value) =
Reactive impedance in hundredths of
ohms (see command 225)
• Bytes 16 through 19 (32-bit value) =
Actual frequency in kHz (see command
147)
• Bytes 20 through 23 (four 8-bit values) =
Process status (see command 162)
• Byte 24 (8-bit value) = Regulation mode
(see command 154)
• Byte 25 (8-bit value) = Control mode
(see command 155)
• Bytes 26 and 27 (16-bit value) =
Coldplate temperature in degrees Celsius
(see command 228)
Reports the real and reactive impedance in
hundredths of ohms.
Returns 8 data bytes (two 32-bit values):
• Bytes 0 through 3 = Signed long integer
value of the real impedance
• Bytes 4 to 7 = Signed long integer value
of the reactive impedance
Communication Controls
®
Paramount
MF 2 kW Generator
Data Bytes
Sent
Returned
0
Data
Bytes
8