Advanced Energy Paramount MF 2 kW User Manual page 66

Generator
Table of Contents

Advertisement

®
Advanced Energy
Table 4‑10. AE Host commands (Continued)
Command
118
set frequency step
minimum (NV)
(subcommand 1)
118
set frequency step
maximum (NV)
(subcommand 2)
118
set step up gain
(NV)
(subcommand 3)
57020114-00E
Description
Byte 0 =
5
Set frequency step start
6
Set gamma threshold high
7
Set gamma threshold low
8
Set maximum tuning count
22
Set tuning step time
23
Set tuning gain delay
50
Set DC bias operating mode
51
Set fixed frequency memory
mode
Sets the frequency tuning frequency step
minimum size in Hz. Valid values must be less
than the frequency step maximum and greater
than 200 Hz.
Send 6 data bytes.
• Bytes 0 and 1 = 1 (set frequency step
minimum)
• Bytes 2 through 5 = Frequency step
minimum
Command 248 reports this value; B0 = 1.
Sets the frequency tuning frequency step
maximum size in Hz. Valid values must be
greater than the frequency step minimum and
less than 100,000 Hz.
Send 6 data bytes.
• Bytes 0 and 1 = 2 (set frequency step
maximum)
• Bytes 2 through 5 = Frequency step
maximum
Command 248 reports this value; B0 = 2.
Sets the magnitude of frequency step increase
when the error is decreasing. A value of
n
the gain to 2
. The default value is 2 (gain =
n
2
2
= 2
= 4). Valid values are 1 to 7.
Communication Controls
Paramount
Subcommand
n
sets
®
MF 2 kW Generator
Data Bytes
Data
Sent
Bytes
Returned
6
1
6
1
4
1
4‑34