Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Advanced Energy Manuals
Inverter
Paramount MF 2 kW
User manual
Electrical Specifications; Table 3-2. Electrical Specifications - Advanced Energy Paramount MF 2 kW User Manual
Generator
Hide thumbs
Advanced Energy
Paramount MF 2 kW
User Manual
1
2
3
4
Table Of Contents
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
page
of
147
Go
/
147
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
®
Advanced Energy
ELECTRICAL SPECIFICATIONS
☞
Important
AE Host command 7 restores all nonvolatile RAM values to factory preset
values. See individual product specifications for factory default parameters.
For more information, contact AE Global Services.
Table 3‑2. Electrical specifications
Description
Input Power
Standard operation
AC facility requirements
• Line voltage
• Line frequency
• Phase
AC to RF efficiency
AC input power factor
AC power consumption
AC line current
Overcurrent protection
RF Output Power
Warm-up time
Frequency tuning range
Frequency stability
57020114-00E
• Nominal: VAC = 208 V, 60 Hz; Low line AC: VAC = 187 V,
60 Hz
• Output power = 2000 W
• Frequency = 400 kHz
• Load = 50 Ω
Facility requirements specification:
• Line voltage: 208 VAC ± 10% (187 VAC to 229 VAC)
• Line frequency: 50 Hz to 60 Hz nominal (47 Hz to 63 Hz)
• Phase: 3φ with ground, no neutral
Nominal: 78%
Low line AC: 79%
Nominal: 0.67
Low line AC: 0.69
Nominal: 2556 W
Low line AC: 2514 W
< 16 A
per phase at 2000 W, 208 VAC
RMS
< 18 A
per phase at 2000 W, low AC line
RMS
50 A circuit breaker with lockout pin
Generator minimum warm-up time of 2 minutes after AC on
360 kHz to 440 kHz
< 50 ppm of selected frequency
Specifications
®
Paramount
MF 2 kW Generator
Specification
3‑3
Table of
Contents
Previous
Page
Next
Page
1
...
19
20
21
22
23
24
25
26
Advertisement
Table of Contents
Troubleshooting
Chapter 6. Troubleshooting and Global Services
127
Troubleshooting Using Error Codes
131
Related Manuals for Advanced Energy Paramount MF 2 kW
Inverter Advanced Energy AE 600 User Manual
(152 pages)
Inverter Advanced Energy AE 3TL 600 Series Installation And Operation Manual
(126 pages)
Inverter Advanced Energy AE 75TX Installation And Operation Manual
(154 pages)
Related Content for Advanced Energy Paramount MF 2 kW
AE 75TX 9-2. Electrical Specifications
Advanced Energy AE 75TX
AE 3TL 600 Series Electrical Specifications
Advanced Energy AE 3TL 600 Series
AE 600 Electrical Specifications
Advanced Energy AE 600
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL