Advanced Energy Paramount MF 2 kW User Manual page 60

Generator
Table of Contents

Advertisement

®
Advanced Energy
Table 4‑10. AE Host commands (Continued)
Command
44
set minimum tuning
frequency
45
set maximum tuning
frequency
46
set tuning start
frequency
57020114-00E
Description
Sets the minimum frequency that the
generator uses for automatic tuning. The unit
stores this parameter in nonvolatile memory.
You cannot change this setting while output is
on.
Send 4 data bytes to set the value in kHz, or 5
data bytes to set the value in either kHz or Hz.
Send 4 data bytes:
• Frequency in kHz
Send 5 data bytes:
• Byte 0 = kHz or Hz
◦ 0 = Frequency is in kHz
◦ 1 = Frequency is in Hz
• Bytes 1 through 4 = Frequency value
Command 144 reports this value.
Sets the maximum frequency that the
generator uses for automatic tuning. The unit
stores this parameter in nonvolatile memory.
You cannot change this setting while output is
on.
Send 4 data bytes to set the value in kHz, or 5
data bytes to set the value in either kHz or Hz.
Send 4 data bytes:
• Frequency in kHz
Send 5 data bytes:
• Byte 0 = kHz or Hz
◦ 0 = Frequency is in kHz
◦ 1 = Frequency is in Hz
• Bytes 1 through 4 = Frequency value
Command 145 reports this value
Sets the frequency at which the generator
starts automatic tuning. The unit stores this
parameter in nonvolatile memory. You cannot
change this setting while output is on.
Communication Controls
®
Paramount
MF 2 kW Generator
Data Bytes
Sent
Returned
4 or 5
4
4 or 5
Data
Bytes
1
1
1
4‑28