Warning And Fault Code Tables; Warning Codes; Table 6-1. Warning Codes - Advanced Energy Paramount MF 2 kW User Manual

Generator
Table of Contents

Advertisement

®
Advanced Energy
• Latching Faults: When these faults occur, regardless of whether RF is off or on
at the time that the fault occurs, they remain latched until the unit receives an
RF off command. If the cause of the fault has not cleared, the fault will not
clear.
• Non-Latching Faults: Faults that are self clearing when RF is off.
◦ Fault occurs when RF is off: A fault is non-latching only if the fault occurs
while RF is off. If the fault condition clears, the fault self clears. If the cause
of the fault has not cleared, the fault does not clear. The unit does not require
an RF off command before turning output on. As soon as the fault condition
clears, you can turn output on.
◦ Fault occurs when RF is on: If output was on when the fault occurred, output
turns off and the fault latches. The unit requires an RF off command before
turning output on.
• Non-Latching Warnings: Warnings self clear when the condition that caused the
warning clears. If a warning occurs while output is on, output remains on.

Warning and Fault Code Tables

The Paramount MF 2 kW generator provides both warning and fault codes for unit
troubleshooting.
• See
Table 6‑1
actions.
• See
Table 6‑2

WARNING CODES

Warning codes can only be accessed through serial communication. Warning 39 also
causes the Power Limit LED on the front panel to light.
Table 6‑1. Warning codes
Warning Code
32
Ambient Air Overtemperature
Warning
57020114-00E
on page 6‑6 for warning code descriptions and suggested
on page 6‑9 for fault code descriptions and suggested actions.
Problem Description
Non-latching warning
• Air temperature is higher
than 60°C (140°F)
Troubleshooting and Global Services
®
Paramount
MF 2 kW Generator
Suggested Action
1. Verify ambient
temperature at air inlet
on the side panel.
2. Verify that there is no
obstruction within
13 mm (0.5") of the air
inlet panel.
If the warning persists, contact
AE Global Services.
6‑6

Advertisement

Table of Contents
loading

Table of Contents