Table 4‑10. AE Host commands (Continued)
Command
155
report active control
mode
158
report retuning
threshold
57020114-00E
Description
Returns 1 data byte (8-bit value):
• 6 = Forward
• 7 = Delivered or real
• 8 = External (DC bias)
Optional: Send 1 data byte (with a value of 0).
Returns 2 data bytes (16-bit value):
• Byte 1:
◦ 6 = Forward
◦ 7 = Delivered or real
◦ 8 = External (DC bias)
• Byte 2 = 0
Set this value with command 3.
Reports the active control mode.
Send 0 or 1 data bytes.
Send 0 data bytes:
Returns 1 data byte (8-bit value):
• 2 = Host
• 4 = User port (analog)
• 8 = Diagnostic
Optional: Send 1 data byte (with a value of 0).
Returns 2 data bytes (16-bit value):
• Byte 1:
◦ 2 = Host
◦ 4 = User port (analog)
◦ 8 = Diagnostic
• Byte 2 = 0
Set this value with command 14.
Reports the tuning criteria level at which the
tuning algorithm determines that the generator
requires retuning. The unit stores this
parameter in nonvolatile memory.
Communication Controls
®
Paramount
MF 2 kW Generator
Data Bytes
Sent
Returned
0 or 1
0
Data
Bytes
1 or 2
4
4‑46