Advanced Energy Paramount MF 2 kW User Manual page 56

Generator
Table of Contents

Advertisement

®
Advanced Energy
Table 4‑10. AE Host commands (Continued)
Command
26
set pulsing mode
(subcommand 1)
26
enable pulse sync
output
(subcommand 2)
26
set memory mode
(subcommand 5)
57020114-00E
Description
The following table shows the factory set/
default values for pulsing parameters.
Parameter
Pulsing mode
Enable pulse sync
output
Memory mode
Sets the unit pulsing mode to master or slave.
You can not use this command while RF
output is on.
Send 6 data bytes.
• Bytes 0 and 1 = 1 (set pulsing mode)
• Bytes 2 and 3 = Pulsing mode
◦ 1 = Master mode
◦ 2 = Slave mode
• Bytes 4 and 5 = Reserved
Command 172 B0 = 1 reports these values.
Enables or disables pulse sync output.
Send 6 data bytes.
• Bytes 0 and 1 = 2 (enable/disable pulse
sync output)
• Bytes 2 and 3 = Pulse sync output on or
off
◦ 0= Pulse sync output off
◦ 1= Pulse sync output on
• Bytes 4 and 5 = Reserved
Command 172 B0 = 2 reports these values.
Sets the unit memory mode to RAM or
NVRAM. The unit saves parameters to the
currently active memory as specified by this
value. Future parameter changes will also be
saved to the current active memory.
Communication Controls
Paramount
Factory Set/
Default Value
Master mode
Pulse sync output
enabled
RAM
®
MF 2 kW Generator
Data Bytes
Data
Sent
Bytes
Returned
6
1
6
1
6
1
4‑24