Table 6‑2. Fault codes (Continued)
Fault Code
54
Onboard Power Fault
55
Measurement FPGA Version
Fault
70
Auxiliary Temperature Fault
71
Auxiliary Cap bank
Temperature Fault
72
Auxiliary Coldplate
Temperature Fault
57020114-00E
Problem Description
• A temperature sensor has
failed
Latching fault
• A voltage regulator has
failed
Internal, unrecoverable fault
• Hardware configuration
fault
Latching fault
• Auxiliary temperature is
higher than 70°C (158°F)
Latching fault
• Cap bank temperature is
higher than 75°C (167°F)
Latching fault
• Auxiliary coldplate
temperature is higher
than 63°C (145°F)
Troubleshooting and Global Services
®
Paramount
MF 2 kW Generator
Suggested Action
If the fault persists, contact AE
Global Services.
Cycle AC power to the unit.
If the fault persists, contact AE
Global Services.
Cycle AC power to the unit.
If the fault persists, contact AE
Global Services.
1. Verify ambient
temperature at air inlet
on the rear panel.
2. Verify that there is no
obstruction within
100 mm (4") of the air
inlet panel on the back of
the unit.
If the fault persists, contact AE
Global Services.
1. Verify ambient
temperature at air inlet
on the rear panel.
2. Verify that there is no
obstruction within
100 mm (4") of the air
inlet panel on the back of
the unit.
If the fault persists, contact AE
Global Services.
1. Verify ambient
temperature at air inlet
on the rear panel.
2. Verify that there is no
obstruction within
100 mm (4") of the air
6‑12