Environmental Specifications; Table 3-4. Environmental Standard Specifications; Table 3-5. Climatic Specifications - Advanced Energy Paramount MF 2 kW User Manual

Generator
Table of Contents

Advertisement

®
Advanced Energy

ENVIRONMENTAL SPECIFICATIONS

Table 3‑4. Environmental standard
specifications
Description
Overvoltage Category
Pollution degree
Table 3‑5. Climatic specifications
Temperature
Operating
+5°C to +40°C
+41°F to +104°F
Storage
-25°C to +55°C
-13°F to +131°F
Transportation
-25°C to +70°C
-13°F to +158°F
1
Non-condensing, no formation of ice
2
Maximum relative humidity when the unit temperature slowly increases, or when the unit temperature
directly increases from -25°C to +30°C (-13°F to +86°F)
3
Maximum absolute humidity when the unit temperature directly decreases from +70°C to +15°C
(+158°F to +59°F)
57020114-00E
Specification
Relative Humidity
5% to 85%
3
1 g/m
to 25 g/m
5% to 95%
3
1 g/m
to 29 g/m
[2]
95%
3 [3]
60 g/m
Specifications
Paramount
II
2
Air Pressure
78.8 kPa to 106 kPa
[1]
788 mbar to 1060 mbar
3
Equivalent altitude: +2000 m
to ‑500 m (+6562' to ‑1640')
78.8 kPa to 106 kPa
3
788 mbar to 1060 mbar
Equivalent altitude: +2000 m
to ‑500 m (+6562' to ‑1640')
65.6 kPa to 106 kPa
656 mbar to 1060 mbar
Equivalent altitude: +3500 m
to ‑500 m (+11483' to
‑1640')
®
MF 2 kW Generator
3‑13

Advertisement

Table of Contents
loading

Table of Contents