Advanced Energy Paramount MF 2 kW User Manual page 74

Generator
Table of Contents

Advertisement

®
Advanced Energy
Table 4‑10. AE Host commands (Continued)
Command
145
report maximum
tuning frequency
146
report tuning start
frequency
57020114-00E
Description
Set this value with command 44.
Reports the maximum frequency that the
generator uses for automatic tuning. The
maximum tuning frequency must be within
the unit's factory-set frequency range. The
unit stores this parameter in nonvolatile
memory.
Send 0 data bytes to return frequency in kHz,
or send 1 data byte to return frequency in kHz
or Hz.
Send 0 data bytes:
• Returns 4 data bytes = Frequency in kHz
Send 1 data byte:
• Byte 0 = Frequency in kHz or Hz
◦ 0 = Returns frequency in kHz
◦ 1 = Returns frequency in Hz
Returns 4 data bytes = Frequency in kHz or
Hz
Set this value with command 45.
Reports the frequency in kHz at which the
generator starts automatic tuning. The tuning
start frequency must be greater than or equal
to the current minimum tuning frequency and
less than or equal to the current maximum
tuning frequency. The unit stores this
parameter in nonvolatile memory.
Send 0 or 1 data bytes.
Send 0 data bytes to return frequency in kHz,
or send 1 data byte to return frequency in kHz
or Hz.
Send 0 data bytes:
• Returns 4 data bytes = Frequency in kHz.
Send 1 data byte:
• Byte 0 = Frequency in kHz or Hz
Communication Controls
®
Paramount
MF 2 kW Generator
Data Bytes
Sent
Returned
0 or 1
0 or 1
Data
Bytes
4
4
4‑42