Advanced Energy Paramount MF 2 kW User Manual page 85

Generator
Table of Contents

Advertisement

®
Advanced Energy
Table 4‑10. AE Host commands (Continued)
Command
172
report memory
mode
(subcommand 5)
193
report pulsing
frequency
196
report pulsing duty
cycle
57020114-00E
Description
◦ 1 = Pulse sync output on
• Bytes 2 and 3 = Reserved
Command 26 B0 = 2 sets these values.
Reports the unit memory mode settings.
Send 2 data bytes.
• Bytes 0 and 1 = 5 (report memory mode)
Returns 4 data bytes.
• Bytes 0 and 1 = Memory mode
◦ 0 = RAM
◦ 1 = NVRAM
• Bytes 2 and 3 = Reserved
Command 26 B0 = 5 sets these values.
Reports the pulsing frequency in Hz. Valid
values range from 10 Hz to 2000 Hz.The unit
may store pulsing frequency values in either
volatile or nonvolatile memory, depending on
the current memory mode (see command 26).
The unit reports the value from the currently
active memory. This command is available in
both master and slave modes.
Returns 4 data bytes:
• Bytes 0 to 3 = Pulsing frequency in Hz.
Command 93 sets this value.
Reports the pulsing duty cycle in increments
of 1%. Valid values range from 10% to 90%.
The unit may store pulsing duty cycle values
in either volatile or nonvolatile memory,
depending on the current memory mode (see
command 26). The unit reports the value
from the currently active memory. When
operating in slave mode, the unit returns CSR
12, Feature Not Available.
Communication Controls
®
Paramount
MF 2 kW Generator
Data Bytes
Sent
Returned
2
0
0
Data
Bytes
4
4
2
4‑53

Advertisement

Table of Contents
loading

Table of Contents