Advanced Energy Paramount MF 2 kW User Manual page 95

Generator
Table of Contents

Advertisement

®
Advanced Energy
Table 4‑10. AE Host commands (Continued)
Command
248
report tuning gain
delay
(subcommand 23)
248
report DC bias
operating mode
(subcommand 50)
57020114-00E
Description
Reports tuning gain delay, which is the delay
before increasing the step size after a change
in direction. Valid values range from 0 to 7.
Send 2 data bytes.
• Bytes 0 and 1 = 23 (tuning gain delay)
Returns 2 data bytes.
• Bytes 0 and 1 = Tuning gain delay
Set this value with command 118; B0 = 23.
Reports the following parameters:
• Power limit setting for external (DC bias)
regulation mode—When operating in
external (DC bias) regulation mode, the
unit uses an internally set value as a
maximum output power limit. In units
without this feature, this parameter is
hard coded to limit forward power. This
feature allows you to set the power limit
to either forward or delivered power.
This parameter reports whether the unit is
set to use forward or delivered power.
• SOA mode—Reports whether the safe
operating area feature is enabled or
disabled
• Memory mode—Reports whether these
settings are volatile or nonvolatile. When
set to volatile, the settings will default to
factory default settings when power to
the unit is cycled. See the product
specifications for factory default settings.
Send 4 data bytes.
• Bytes 0 and 1 = 50 (report DC bias
operating mode)
• Bytes 2 and 3 = Select parameter to
report:
◦ 1 = DC bias mode
◦ 2 = SOA mode
Communication Controls
®
Paramount
MF 2 kW Generator
Data Bytes
Sent
Returned
2
4
Data
Bytes
2
4
4‑63