Advanced Energy Paramount MF 2 kW User Manual page 71

Generator
Table of Contents

Advertisement

®
Advanced Energy
Table 4‑10. AE Host commands (Continued)
Command
129
report power supply
size
130
report software part
number
57020114-00E
Description
Returns a nonterminated 9-character ASCII
string that represents the power supply type
(PT-MF).
Send 1 data byte:
• Byte 0 = 3
Returns 10 bytes:
• Bytes 0 through 3 = 4 ASCII characters
• Bytes 4 through 9 = Six-digit ASCII
representation of the 3 least significant
bytes of the unit MAC ID.
Reports the power supply size in kW, in four
or six digits, depending on the sent data bytes.
Send 0 or 1 data bytes.
Send 0 data bytes:
• Returns four data bytes = Power supply
size formatted to four ASCII characters.
Optional: Send 1 data byte (with a value of 0):
• Returns six data bytes = Power supply
size formatted to six ASCII characters,
right justified.
Reports the software part number. Returns a
nonterminated ASCII string that represents the
AE software part number (for example,
"7432006"). You can use this number in
conjunction with the revision number returned
by command 198 to identify the software in
the unit.
Sending a request data byte is optional. You
can send 0 data bytes or 1 data byte.
Send 0 data bytes.
• Returns Coldfire application firmware
part number.
Communication Controls
®
Paramount
MF 2 kW Generator
Data Bytes
Sent
Returned
0 or 1
characters
0 or 1
7 ASCII
characters
Data
Bytes
4 or 6
ASCII
4‑39

Advertisement

Table of Contents
loading

Table of Contents