8. Remove AC power from the unit by taking one or both of the following actions:
◦ Turn off the circuit breaker.
◦ Disconnect AC power.
9. Prepare the output connector for normal operation.
a. Remove the RF output connector cover on the RF output.
b. Connect the RF output cable.
c. Install the RF output connector cover.
10. Restore AC power to the unit by taking one or both of the following actions:
◦ Reconnect AC power.
◦ Turn on circuit breaker.
11. Issue command 14 to reset the control mode.
The unit is ready for normal operation.

TROUBLESHOOTING USING ERROR CODES

Accessing Error Codes

You can access Paramount MF 2 kW generator error codes in two ways:
• You can view active error codes on the front panel display. The display will
scroll through the active error codes, showing each for about one second. If
there is only one error code, it is displayed continuously.
• You can use serial communication to request a report of active warning or fault
error codes (command 223). Once you have received a list of active errors, see
the error code table to look up these error codes and troubleshoot the associated
faults or warnings.
 Important
Only active fault error codes will show on the front panel display. Warning
error codes do not display on the front panel. Therefore, if you see an error
code displayed on the front panel, it is a fault code, not a warning.

Fault and Warning Types and Clearing Faults

The unit can report one or more types of faults or warnings:
• Unrecoverable Fault: This type of fault can occur at initialization or after
running. You can try to clear it by AC power cycling the unit. If the fault
persists, contact AE Global Services.
57020114-00E
Troubleshooting and Global Services
®
Paramount
MF 2 kW Generator
6‑5