Advanced Energy
Table 4‑10. AE Host commands (Continued)
Command
248
report frequency
step minimum
(subcommand 1)
248
report frequency
step maximum
(subcommand 2)
248
report step up gain
(subcommand 3)
57020114-00E
Description
Byte 0 =
8
Report maximum tuning
count
22
Report tuning step time
23
Report tuning gain delay
50
Report DC bias operating
mode
51
Report fixed frequency
memory mode
Reports the frequency step minimum used
during the tuning process. This is the smallest
step size used by the tuning algorithm when
making frequency step changes.
Send 2 data bytes.
• Bytes 0 and 1 = 1 (report frequency step
minimum)
Returns 4 data bytes:
• Bytes 0 through 3 = Frequency step
minimum in Hz (unsigned long)
Set this value with command 118; B0 = 1.
Reports the frequency step maximum used
during the tuning process. This is the largest
step size used by the tuning algorithm when
making frequency step changes.
Send 2 data bytes.
• Bytes 0 and 1 = 2 (report frequency step
maximum)
Returns 4 data bytes:
• Bytes 0 through 3 = Frequency step
maximum in Hz (unsigned long)
Set this value with command 118; B0 = 2.
Reports the step up gain used during the
tuning process. This parameter sets the
magnitude of frequency step increase when
Communication Controls
Paramount
Subcommand
®
MF 2 kW Generator
Data Bytes
Data
Sent
Bytes
Returned
2
4
2
4
2
4
4‑60