Generator Leds; Table 5-5. Generator Leds - Advanced Energy Paramount MF 2 kW User Manual

Generator
Table of Contents

Advertisement

®
Advanced Energy
Table 5‑4. Status LED indicators (Continued)
Status LED
Over-temp
Fault

Generator LEDs

Table 5‑5. Generator LEDs
Generator LED
Forward Power
Reflected Power
Load Power
External Volts
Power Set Point
External Set Point
Frequency
57020114-00E
When lit, this yellow LED indicates that the unit's internal
temperature has exceeded its allowable level. The unit's output
power will be disabled until the temperature falls below the
internal temperature limit and the RF on command is toggled.
When lit, this yellow LED indicates that the unit has a fault
condition. The display will scroll through all error codes which
caused the fault.
While fault conditions are active, the unit's output power will be
disabled. Once the fault condition is cleared, send an RF off
command and then an RF on command, and output will be
enabled.
Display Value Description
Displays forward power in watts.
Displays reflected power in watts.
Displays load power in watts.
Displays voltage on the SMA connector Sense Voltage In in
volts, multiplied by 200 (10 V is displayed as 2000 V).If nothing
is connected to the Sense Voltage In connector, the display
shows 2000 V.
When the unit is in power control mode, displays power set point
in watts. When the unit is in voltage control mode, the display
will be dark when you scroll to this LED.
When the unit is in power control mode, the display will be dark
when you scroll to this LED.
When the unit is in voltage control mode, displays the voltage set
point in volts, multiplied by 200 (10 V is displayed as 2000 V).
Displays output frequency in kHz.
Installation, Setup, and Operation
®
Paramount
MF 2 kW Generator
Description
5‑18