2. Plug the Ethernet cable into the Ethernet port on the communication interface
PCB located in the data monitoring section of the inverter. Refer to the
following figure for the port location.
Figure 6‑2. Communication interface PCB Ethernet port location
Related Links
• "Conduit Entry Points" on page 4-12
To Establish an Internet Connection with the Inverter
Below is a list of requirements to establish inverter communications with the AE data
center. Connectivity must be established before registration on the site is attempted.
1. Connect the inverter's Ethernet port to a hub or router using an Ethernet cable.
Ethernet cables must meet the T-568B wiring standard and must be less than
320 feet in length. If a longer cable is needed additional networking hardware
may be required.
2. Provide DHCP server access to the inverter and provide a path to the Internet
for https (port 443) from the inverter.
As shipped, the inverter requires DHCP to establish its IP address. Contact AE
Solar Energy Technical Support if a fixed IP address is required for your
network.
3. Locate the inverter's MAC address on the label on the communications
interface PCB.
The communications interface PCB must be removed from the card cage
assembly to see the MAC address.
When the Internet connection is established, go to the AE web site and navigate to
the PVP Commercial Monitoring page to register the inverter and begin using the
570-1001791-05A
Ethernet port
Data Monitoring and Controls
Advanced Energy® AE 500 Inverter
6‑3