Table 8‑7. System (SYS) faults (Continued)
Display
Display Screen Text
Screen Hex
Value
0008
WD TIMER
0010
CPU LOAD
0020
RESTART LIMIT
0040
CONFIGURATION
0080
CURRENT
IMBALANCE
0100
AC VOLTAGE SENSE
0800
DISCONNECT OPEN
1000
DC MISWIRE
PCB STATUS LEDS
The AE commercial inverter includes status LEDs to help troubleshoot system
operation. The status LEDs are located on the following PCBs:
• Controller PCB
• Communications interface PCB
Controller PCB Status LEDs
There are two LEDs on the front of the controller PCB, a green and a red LED.
Table 8‑8. Controller PCB LEDs
LED
Flash
Color
Code
Green
Solid
Inverter is on and ready to
produce power.
570-1001791-05A
Watchdog fault
CPU load fault
Too many fault restarts
Configuration fault
AC current imbalance
No AC voltage detected
Disconnect open
DC mis-wired for
configured grounding
LED Sequence / Unit
Status
Troubleshooting and Solar Energy Technical Support
Advanced Energy® AE 500 Inverter
Description
Contact AE Solar
Energy Technical
Support for service.
Check the DC wiring.
Action
None
Action
8‑13