HP MC68040 User Manual page 578

Emulator, graphical user interface
Table of Contents

Advertisement

Chapter 12: Emulator Error Messages
Unable to reset (Error 640)
Unable to reset (Error 640)
Cause: Target condition or system failure.
Action: Check target system, and run performance verification (pv command).
Unable to run (Error 610)
Cause: Run has failed for some reason. For example, this message will appear if
the emulator cannot write to stack, which is required to run. Usually, this error
message will occur with other error messages.
Action: Refer to the descriptions of the accompanying error messages to find out
more information about why the run failed. Look at the emulator prompt to know
the emulator status. Take a trace with the analyzer to see where the emulator is
executing.
Unable to run after CMB break (Error 606)
Cause: System failure or target condition.
Action: Run performance verification (pv command), and check target system.
Unable to run HP64783 performance verification tests (Error 178)
Cause: You entered the pv command, but the emulator was unable to start
performance verification because the firmware did not identify the probe as being
the MC68040.
Action: Make sure the correct emulator probe is connected and that all cables are
secured. Make sure that the demo board is connected to the emulator probe, the
power cable is connected between the HP 64700 card cage and the demo board, and
the reset flying lead is connected between the emulation probe and the demo board.