To Select Whether Or Not The Emulation-Bus Analyzer Will Operate With, Or Ignore, The Trig2 Line Of The Coordinated Measurement Bus - HP MC68040 User Manual

Emulator, graphical user interface
Table of Contents

Advertisement

Chapter 8: Configuring the Emulator
Modifying the Interactive Measurement Specification Configuration Items
To select whether or not the emulation-bus
analyzer will operate with, or ignore, the Trig2
line of the coordinated measurement bus.
• Choose "Drive", "Receive", or "Neither" for the "Analyzer on Trig2" specification.
Choosing "Drive" specifies that the emulation-bus analyzer will drive a trigger
signal on the Trig2 line of the coordinated measurement bus when it recognizes its
trigger condition during a trace.
Choosing "Receive" specifies that the emulation-bus analyzer will receive the
signal on the Trig2 line of the coordinated measurement bus when it is supplied,
and it will mark the state that it is capturing as the trigger state at the instant when
the Trig2 signal is detected.
Choosing "Neither" specifies that the emulation-bus analyzer will ignore the Trig2
line of the coordinated measurement bus.
Refer to Chapter 16, "Specifications and Characteristics", in this manual for the
electrical specifications of the Trig1 and Trig2 trigger signals.
348