Chapter 12: Emulator Error Messages
Label not defined: <label> (Error 321)
Label not defined: <label> (Error 321)
Cause: You entered an analyzer expression in which the label was not present in the
analyzer label list. For example, if the label list includes address, data, and status,
you might have entered something such as lowerdata=24t. This error also occurs if
you try to delete a label that does not exist.
Action: You can reenter the command, using one of the previously defined labels,
and adjust the expression as necessary to accommodate the fit of that label to the
analyzer input lines. You can also define a new label using the tlb command, and
then reenter the analyzer command using the newly defined label.
Loaded deMMUer file: <FILE>
Cause: This is a status message. It indicates that the deMMUer was successfully
loaded from a configuration file.
Loaded deMMUer from MMU translation tables
Cause: This is a status message. It indicates that the deMMUer was successfully
loaded from the MMU translation tables in memory.
Map range overlaps with term: <term number> (Error 734)
Cause: You entered a map term whose address range overlaps with one already
mapped.
Action: Reenter the map term so that ranges do not overlap, or combine terms and
change the memory type.