To drive the external analyzer trigger signal to the BNC connector

To drive the external analyzer trigger signal to the
BNC connector
Choose "receive" for the "Should BNC drive or receive Trig2"
1
configuration option.
Choose "drive" for the "Should External Analyzer drive or receive
2
Trig2" configuration option.

To break emulator execution on signal from CMB

Choose "drive" for the "Should CMBT drive or receive Trig1"
configuration option.
You could also break emulator execution on a trigger signal from the CMB
over the trig2 internal line by specifying that the CMB should drive trig2 and
that the emulator break should receive trig2.

To break emulator execution on signal from BNC

Choose "drive" for the "Should BNC drive or receive Trig1"
configuration option.
You could also break emulator execution on a trigger signal from the BNC
over the trig2 internal line by specifying that the BNC should drive trig2 and
that the emulator break should receive trig2.
To break emulator execution on external analyzer
trigger
Choose "yes" for the "Should Emulator break receive Trig2"
1
configuration option.
Choose "drive" for the "Should External Analyzer drive or receive
2
Trig2" configuration option.
When an emulator break occurs due to the analyzer trigger, the analyzer will
stop driving the internal signal that caused the break. Therefore, if trig2 is
used both to break and to drive the CMB TRIGGER (for example), TRIGGER
will go true when the trigger is found and then will go false after the emulator
Making Coordinated Measurements