To select the type of count information in the trace list

Choose Trace→Display Options... and in the dialog box, select
Count Format Relative or Absolute, as desired. Then click the OK or
Apply pushbutton.
To display count information in the trace list relative to the trigger
state, enter:
display trace count absolute
To display count information in the trace list relative to the previous
trace list state, enter:
display trace count relative
Count information may be displayed two ways: relative (which is the default),
or absolute. When relative is selected, count information is displayed relative
to the previous state. When absolute is selected, count information is
displayed relative to the trigger condition.
The count information in the trace list is always displayed if count display is
turned on. To turn on the trace counting function, enter a command
beginning with trace counting on the command line. Refer to "To count
states or time" later in this manual for details.
When using the 1K analyzer, the trace memory is 512 states deep if counting
states or time is turned on and 1024 states deep if counting is turned off. To
disable counting in the 1K analyzer, use the command trace counting off.
When using the deep analyzer, full memory depth is always available; the
depth of the deep analyzer is not affected by the counting selected. See "To
count states or time."
Using the Emulation Analyzer
To select the type of count information in the trace list