To Arm The Emulation Analyzer On Signal From Cmb; To Arm The Emulation Analyzer On Signal From Bnc; To Arm The Emulation Analyzer On External Analyzer Trigger - HP 64782 User Manual

For the graphical user interface
Hide thumbs Also See for 64782:
Table of Contents

Advertisement

Making Coordinated Measurements

To arm the emulation analyzer on signal from CMB

breaks. However, if trig1 is used to cause the break and trig2 is used to drive
the CMB TRIGGER, TRIGGER will stay true until the trace is halted or until
the next trace starts.
To arm the emulation analyzer on signal from CMB
Choose "drive" for the "Should CMBT drive or receive Trig2"
1
configuration option.
Choose "receive" for the "Should Analyzer drive or receive Trig2"
2
configuration option.
Use the arm_trig2 option to the trace command.
3

To arm the emulation analyzer on signal from BNC

Choose "drive" for the "Should BNC drive or receive Trig2"
1
configuration option.
Choose "receive" for the "Should Analyzer drive or receive Trig2"
2
configuration option.
Use the arm_trig2 option to the trace command.
3
To arm the emulation analyzer on external analyzer
trigger
Choose "receive" for the "Should Analyzer drive or receive Trig2"
1
configuration option.
Choose "drive" for the "Should External Analyzer drive or receive
2
Trig2" configuration option.
Use the arm_trig2 option to the trace command.
3