Emulator/Analyzer Interface Commands

SEQUENCING

SEQUENCING
Lets you specify complex branching activity that must be satisfied to trigger
the analyzer.
Sequencing provides you with parameters for the trace command that let
you define branching conditions for the analyzer trigger.
You are limited to a total of seven sequence terms, including the trigger, if no
windowing specification is given. If windowing is selected, you are limited to
a total of four sequence terms.
The analyzer default is no sequencing terms. If you select the sequencer
using the find_sequence parameter, you must specify at least one qualifying
sequence term.
The parameters are as follows:
find_sequence
Specifies that you want to use the analysis sequencer. You must enter at least
one qualifier.
QUALIFIER
Specifies the address, data, status, or executed address value or value range
that will satisfy this sequence term if looking for a sequence (find_sequence),
or will restart at the beginning of the sequence (restart). See the
QUALIFIER syntax pages for further information.