Note that when a trigger condition is found but not enough states are
captured to fill trace memory, the status line will show the trace is still
running. You can display all but the last captured state in this situation; you
must halt the trace to display the last captured state.
To display the trace status
•
Choose Display→Status.
•
Using the command line, enter the display status command.
In addition to the analyzer information shown on the status line (Emulation
trace started, Emulation trace complete, etc.), you can display complete
analyzer status with the command below.
Examples
To display the trace status:
display status
display status
The first line of the emulation trace status display shows the user trace has
been "completed"; other possibilities are that the trace is still "running" or
that the trace has been "halted".
The second line of the trace status display contains information on the arm
condition. If the analyzer is always armed, the message "Arm ignored" is
displayed. If the analyzer is to be armed by one of the internal signals, either
Using the Emulation Analyzer
To display the trace status
199