Silicon Graphics Origin 300 User Manual page 241

System with numalink module
Table of Contents

Advertisement

007-4498-002
For the power command set, the mnemonics pwr, u, and d may replace the words power,
up, and down.
Use the power command to view the power status of each module identified by the
destination set of commands. Use the power up and power down commands to power
up or power down each module identified by the destination set of commands.
Example C-54 shows sample output from the power command.
Example C-54
power
L2> power
001c20:
power appears on
001c22:
power appears on
001c24:
power appears on
001c26:
power appears on
001r28:
power appears on
001c30:
power appears on
001c32:
power appears on
001c34:
power appears on
001c36:
power appears on
Use the r <rack> s <slot> power command to view the power status of a specified
brick. Use the r <rack> s <slot> power up and r <rack> s <slot> power down
command to power up or power down specified modules. In these commands, the
variable <rack> is a rack number, and the variable <slot> is a slot number. Example C-55
shows sample output from the r <rack> s <slot> power command.
r <rack> s <slot> power
Example C-55
L2> r 1 s 22 power
power appears on
Command Output
Command Output