C: System Controller Commands
multisys
nvram reset
power
214
The multisys set of commands displays the current setting for multiple-system
network sharing, enables communication between L2 controllers that have the same
system serial number, and enables communication between all L2 controllers.
•
multisys
•
multisys on (enables communication between L2 controllers with the same
system serial number)
•
multisys off (enables communication between all L2 controllers)
Example C-53 shows sample output from the multisys command.
Example C-53
multisys Command Output
L2>multisys
L2 multiple system network support enabled.
L2's will only connect to L2's with same system SN
The nvram reset command returns the NVRAM settings of the L2 controller to the
factory default settings.
The power set of commands displays the status of the supplies or powers up and powers
down the supplies:
•
power
•
power up
•
power down
•
r <rack> s <slot> power
•
r <rack> s <slot> power up
•
r <rack> s <slot> power down
007-4498-002