Silicon Graphics Origin 300 User Manual page 135

System with numalink module
Table of Contents

Advertisement

007-4498-002
L1 Controller Messages (continued)
Table 5-2
L1 System Controller Message
Temperature messages: low alt.
ATTN: TEMP # advisory temperature reached
@ xxC xxF
ATTN: TEMP # critical temperature reached
@ xxC xxF
ATTN: TEMP # fault temperature reached
@ xxC xxF
Temperature messages: high alt.
ATTN: TEMP # advisory temperature reached
@ xxC xxF
ATTN: TEMP # critical temperature reached
@ xxC xxF
ATTN: TEMP # fault temperature reached @
xxC xxF
Temperature stable message:
ATTN: TEMP # stabilized @ xxC/xxF
Power off messages:
Auto power down in xx seconds
Base module appears to have been powered
down
L1 Controller Error Messages
Message Meaning and Action Needed
The ambient temperature at the module's air
inlet has exceeded 30 ˚C.
The ambient temperature at the module's air
inlet has exceeded 35 ˚C.
The ambient temperature at the module's air
inlet has exceeded 40 ˚C.
The ambient temperature at the module's air
inlet has exceeded 27 ˚C.
The ambient temperature at the module's air
inlet has exceeded 31 ˚C.
The ambient temperature at the module's air
inlet has exceeded 35 ˚C.
The ambient temperature at the module's air
inlet has returned to an acceptable level.
The L1 controller has registered a fault and is
shutting down. The message displays every 5
seconds until shutdown.
The L1 controller has registered a fault and has
shut down.
109