Margin; Network - Silicon Graphics Origin 300 User Manual

System with numalink module
Table of Contents

Advertisement

margin

network

007-4498-002
The margin set of commands displays the state of the supply margins or sets the state of
the supply margins. There are three commands in the margin command set: margin,
margin default, and margin <low|norm|high>. For the margin command set, the
mnemonic mgn may replace the word margin.
Use the margin command to view the current state of the margin values for the supplies
in a module. Example C-22 shows sample output from the margin command.
margin Command Output
Example C-22
001c20-L1>margin
Supply
State Voltage
--------------
----- ---------
2.5V
Speedo2 CPU
1.5V
Use the margin default command to set the margin values for the supplies to their
default values. Use the margin <low|norm|high> command to set the margin values for
the supplies to the low-margin, normal-margin, or high-margin values. In this command,
the variable <low|norm|high> is low (low-margin), norm (normal margin), or high (high
margin). Example C-23 shows sample output from the margin default command.
margin default Command Output
Example C-23
001c20-L1>margin default
The following network set of commands displays and sets the mode for the network
communication interface.
network
network usb
network 422
network autodetect|auto on
network autodetect|auto off
Margin
------- -----
on
2.483V
normal
on
1.495V
normal
on
1.480V
normal
L1 Controller Command Set
Value
3
19
5
193

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Origin 300 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents