Parameters
Reference
7.2.12
AT+CIFSREX Get Local IP Address
AT+CIFSREX Get Local IP Address
Test Command
AT+CIFSRREX=?
Execution Command
AT+CIFSRREX
Parameters
Reference
7.2.13
AT+CIPSTATUS Query Current Connection Status
AT+CIPSTATUS Query Current Connection Status
Test Command
AT+CIPSTATUS=?
Write Command
If
multi
IP
connection
mode(+CIPMUX=1)
AT+CIPSTATUS=<n>
Execution Command
AT+CIPSTATUS
SIM5300E AT Command Manual V1.02
If error is related to ME functionality:
+CME ERROR: <err>
<IP address> a string parameter which indicates the IP address assigned
from GPRS.
Note:
Only after PDP context is activated, local IP Address can be obtained by
AT+CIFSR, otherwise it will respond ERROR. The active status are IP
GPRSACT, TCP/UDP CONNECTING, CONNECT OK, IP CLOSE.
Response
OK
Response
+CIFSREX: <IP address>
OK
If error is related to ME functionality:
+CME ERROR: <err>
<IP address> a string parameter which indicates the IP address assigned
from GPRS.
Response
OK
Response
+CIPSTATUS: <n>,<bearer>, <TCP/UDP>, <IP address>, <port>, <client state>
OK
Response
1)If in single connection mode (+CIPMUX=0)
OK
STATE: <state>
2) If in multi-connection mode (+CIPMUX=1)
OK
158