Read Command
AT+ICF?
Write Command
AT+ICF=<format>[,<parity>]
Parameters
Reference V.25ter
2.2.24
AT+IFC Set TE-TA Local Data Flow Control
AT+IFC Set TE-TA Local Data Flow Control
Test Command
AT+IFC=?
Read Command
AT+IFC?
Write Command
AT+IFC=<dce_by_dte>,<dte_by
_dce>
Parameters
SIM5300E AT Command Manual V1.02
Response
+ICF: <format>,<parity>
OK
Response
This parameter setting determines the serial interface character framing
format and parity received by TA from TE.
OK
<format>
1
8 data 0 parity 2 stop
2
8 data 1 parity 1 stop
3
8 data 0 parity 1 stop
4
7 data 0 parity 2 stop
5
7 data 1 parity 1 stop
6
7 data 0 parity 1 stop
<parity>
0
odd
1
even
3
space (0)
Note:
The Command is applied for Command state;
In <format> parameter, "0 parity" means no parity;
Response
+IFC: (list of supported <dce_by_dte>s),(list of supported<dte_by_dce>s)
OK
Response
+IFC: <dce_by_dte>,<dte_by_dce>
OK
Response
This parameter setting determines the data flow control on the serial
interface for data mode.
OK
<dce_by_dte> Specifies the method will be used by TE at receive of data
from TA
0
No flow control
1
Software flow control
18