Reference
7.2.6
AT+CIPCLOSE Close TCP or UDP Connection
AT+CIPCLOSE Close TCP or UDP Connection
Test Command
AT+CIPCLOSE=?
Write Command
1) If single IP connection
(+CIPMUX=0)
AT+CIPCLOSE=<n>
2)
If
multi
IP
connection
(+CIPMUX=1)
AT+CIPCLOSE=<id>, [<n>]
Execution Command
AT+CIPCLOSE
Parameters
Reference
7.2.7
AT+CIPSHUT Deactivate GPRS PDP Context
AT+CIPSHUT Deactivate GPRS PDP Context
SIM5300E AT Command Manual V1.02
<txlen> The data amount which has been sent
<acklen> The data amount confirmed successfully by the server
<nacklen> The data amount without confirmation by the server
Response
OK
Response:
1) For single IP connection (+CIPMUX=0)
CLOSE OK
2) For multi IP connection (+CIPMUX=1)
<n>, CLOSE OK
Response
If close is successfully:
CLOSE OK
If close fails:
+CME ERROR: <err>
<n>
0
Slow close
1
Quick close
<id>
A numeric parameter which indicates the connection number
Note:
AT+CIPCLOSE only closes connection at the status of TCP/UDP which
returns CONNECTING or CONNECT OK, otherwise it will return ERROR,
after the connection is closed, the status is IP CLOSE in single IP mode.
154
Need help?
Do you have a question about the SIM5300E and is the answer not in the manual?