At+Cipclose Close Tcp Or Udp Connection; At+Cipshut Deactivate Gprs Pdp Context - SimCom SIM5300E At Command Manual

Hide thumbs Also See for SIM5300E:
Table of Contents

Advertisement

Reference
7.2.6

AT+CIPCLOSE Close TCP or UDP Connection

AT+CIPCLOSE Close TCP or UDP Connection
Test Command
AT+CIPCLOSE=?
Write Command
1) If single IP connection
(+CIPMUX=0)
AT+CIPCLOSE=<n>
2)
If
multi
IP
connection
(+CIPMUX=1)
AT+CIPCLOSE=<id>, [<n>]
Execution Command
AT+CIPCLOSE
Parameters
Reference
7.2.7

AT+CIPSHUT Deactivate GPRS PDP Context

AT+CIPSHUT Deactivate GPRS PDP Context
SIM5300E AT Command Manual V1.02
<txlen> The data amount which has been sent
<acklen> The data amount confirmed successfully by the server
<nacklen> The data amount without confirmation by the server
Response
OK
Response:
1) For single IP connection (+CIPMUX=0)
CLOSE OK
2) For multi IP connection (+CIPMUX=1)
<n>, CLOSE OK
Response
If close is successfully:
CLOSE OK
If close fails:
+CME ERROR: <err>
<n>
0
Slow close
1
Quick close
<id>
A numeric parameter which indicates the connection number
Note:
AT+CIPCLOSE only closes connection at the status of TCP/UDP which
returns CONNECTING or CONNECT OK, otherwise it will return ERROR,
after the connection is closed, the status is IP CLOSE in single IP mode.
154