Technical Data Cx1500-M510; Connections Cx1500-M510 / B510 - Beckhoff CX1500-M510 Manual

Canopen - bus interfaces for cx systems
Table of Contents

Advertisement

2.1.1

Technical data CX1500-M510

Technical data
Fieldbus
Transmission rate
Bus connection
Bus nodes
Max. I/O-size
Interface to the CPU
Max. power consumption
Dimensions
Weight
Operating temperature
Storage temperature
Relative humidity
Vibration/shock resistance
EMC resistance burst /ESD
Protection class
2.1.2

Connections CX1500-M510 / B510

The connection to the CANopen bus is realized by a 5 pin open style connector.
   
       
The pin of the connector have the following definition:
Pin
1
2
3
4
5
More details to the connection are described in the chapter bus description.
CX1500-M510, CX1500-B510
CX1500-B310
CANopen
10, 20, 50, 100, 125, 250, 500, 800, 1000 kBaud
Open-Style-Connector, 5-polig
max. 127 slaves
1536 Bytes Input / 1536 Byte Output
16 bit ISA (PC104-Standard) / 2 kbyte DPRAM
1,8 W
38 mm x 100 mm x 91 mm
190 g
0 °C ... +55 °C
-25 °C ... +85 °C
95% no condensation
confirms to EN 60068-2-6 / EN 60068-2-27/29
confirms to EN 61000-6-2 / EN 61000-6-4
IP 20
Meaning
reserved
CAN - High
Shield
CAN - Low
Ground
Version: 1.0
Product overview
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cx1500-b510Cx1500-b310

Table of Contents