SSD replacement procedures when the SSD replacement is indicated.
*: Data transfer by U026 is not available since data cannot be read when SSD is broken or it is in Read
Only mode.
Procedures
Preparation: 2 USB memory (for firmware and data backup)
Before operating, perform data backup in U917.
(1)Firmware storage in a USB memory (USB memory A)
1. Store the firm upgrade pack of latest version in USB memory or release firmware (Main/MMI/
BROWSER/DICTIONARY/LANGUAGE/OCR).
*: Check the firmware applicable to the target model. When inputting the software of outside the target,
becomes unstable in action.
In order to reboot, require minimum main.
(2)SSD data backup (USB memory B)
*: When fully back up 32G SSD, it need 64GB USB memory.
1. Install the USB memory B.
2. Execute maintenance mode U026
Input "026" using the numeric keys and press the [Start] key.
Select [SSE].
Select [Backup]. Press the [Start] key.
Turn the power off after completion.
3. Replace the new SSD.
*: When equipping with SSD (8G/32G) which the capacity is different from the specification, pay attention
as F010 SSD and communication error happen.
4. Turn ON the power with equipping with USB memory A.
As the program from SSD can't load, SSD recovery program which is SNOR on the main PWB start up,
is formatted automatically.
*: When forgot the USB memory equipment, pay attention as F010 displays.
5. If UPDATE completion is displayed on the control panel, turn OFF/ON the power with inserted USB
memory A.
(3)Update firmware. (See page 1-6-1)
(4)Retrieve the data backed up in the USB memory B.
(5)Install from HyPAS application(FMU), application screen.
*: Check the kind of HyPAS application which is displayed in the application screen before replacing and
reinstall.