Setting: Staple HP
1.Select [Staple HP].
2.By using the [+] [-] keys or the numeric keys, change the setting value.
Front/rear staple home position adjustment
*: Increase the set value if the staple position is shifted to the machine front side (sample1).
Lower the set value if the staple position is shifted to the machine rear side (sample2).
3.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
*: The screen for selecting a maintenance item No. is displayed.
Content to adjust
Sample 1
1-3-104
Setting
range
-30 to 30
Sample 2
2RG/2RH
Initial setting
Data varia-
tion
0
0.97mm