(2-5) U010XX error code table: G3 transmission
Error code
U01000/E01000 An FTT signal was received for a set number of times after TCF signal transmission at
2400 bps. Or, an RTN signal was received in response to a Q signal (excluding EOP)
after transmission at 2400 bps.
U01001/E01001 Function of the unit differs from that indicated by a DIS signal.
U01010/E01010 No relevant signal was received after transmission of a DNL (MPS or EOM) signal, and
the preset number of command retransfers was exceeded (between units of our make).
U01011/E01011
No relevant signal was received after transmission of a DCS, TCF signal, and the preset
number of command retransfers was exceeded.
U01012/E01012 No relevant signal was received after transmission of an NSS1, NSS2 (TCF) signal, and
the preset number of command retransfers was exceeded (between units of our make).
U01013/E01013 No relevant signal was received after transmission of an NSS3, TCF signal, and the pre-
set number of command retransfers was exceeded (between units of our make).
U01014/E01014 No relevant signal was received after transmission of an MPS signal, and the preset
number of command retransfers was exceeded.
U01015/E01015 No relevant signal was received after transmission of an EOM signal, and the preset
number of command retransfers was exceeded.
U01016/E01016 An MCF signal was received but no DIS signal was received after transmission of an
EOM signal, and T1 timeout was detected.
U01017/E01017 No relevant signal was received after transmission of an EOP signal, and the preset
number of command retransfers was exceeded.
U01018/E01018 No relevant signal was received after transmission of a PRI-EOP signal, and the preset
number of command retransfers was exceeded.
U01019/E01019 No relevant signal was received after transmission of a CNC signal, and the preset num-
ber of command retransfers was exceeded (between units of our make).
U01020/E01020 No relevant signal was received after transmission of a CTC signal, and the preset num-
ber of command retransfers was exceeded (ECM).
U01021/E01021 No relevant signal was received after transmission of an EOR.Q signal, and the preset
number of command retransfers was exceeded (ECM).
U01022/E01022 No relevant signal was received after transmission of an RR signal, and the preset num-
ber of command retransfers was exceeded (ECM).
U01023/E01023 No relevant signal was received after transmission of a PSS.NULL signal, and the preset
number of command retransfers was exceeded (ECM).
U01024/E01024 No relevant signal was received after transmission of a PSS.MPS signal, and the preset
number of command retransfers was exceeded (ECM).
U01025/E01025 No relevant signal was received after transmission of a PPS.EOM signal, and the preset
number of command retransfers was exceeded (ECM).
U01026/E01026 No relevant signal was received after transmission of a PPS.EOP signal, and the preset
number of command retransfers was exceeded (ECM).
U01027/E01027 No relevant signal was received after transmission of a PPS.PRI-EOP signal, and the
preset number of command retransfers was exceeded (ECM).
U01028/E01028 T5 time-out was detected during ECM transmission (ECM).