Kyocera Copystar CS 3011i Service Manual page 389

Table of Contents

Advertisement

Error code
U01152/E01152
A DCN signal was received after transmission of a CTR signal (ECM).
U01153/E01153
A DCN signal was received after transmission of an ERR signal (ECM).
U01154/E01154
A DCN signal was received after transmission of an RNR signal (ECM).
U01155/E01155
A DCN signal was received after transmission of an SPA signal (short protocol).
U01160/E01160
During message reception, transmission time exceeded the maximum transmission time
per line.
U01161/E01161
Number of error lines exceeded limits during message reception.
U01162/E01162
A break in loop current was detected during message reception.
U01163/E01163
Polarity reversal was detected during message reception.
U01164/E01164
One page length exceeded the specified length during message reception.
U01170/E01170
A decoding error occurred during MMR message reception.
U01172/E01172
During reverse polling in V.34 mode at the transmitting unit, a JM signal was not
detected after transmission of a CM signal when receiving after transmission.
U01191/E01191
Communication was interrupted because an error occurred during an image data recep-
tion sequence in the V.34 mode.
U01199/E01199
A DIS signal with different FIF was received after transmission of a DIS signal.
(2-7) U017XX error code table: V.34 transmission
Error code
U01700/E01700 A communication error occurred in phase 2 (line probing).
U01720/E01720 A communication error occurred in phase 4 (modem parameter exchange).
U01721/E01721 Operation was interrupted due to the absence of a common communication speed
between units.
U01700: A communication error that occurs at the transmitting unit in the period after transmission of INFO0
before entering phase 3 (primary channel equivalent device training). For example, INFO0/A/Abar (B/Bbar, for
polling transmission)/INFOh was not detected.
U01720: A communication error that occurs at the transmitting unit in the period after initiating the control
channel before entering the T.30 process. For example, PPh/ALT/MPh/E was not detected.
U01721: In the absence of a common communication speed between units (including when an impossible
combination of communication speed and symbol speed occurs) after MPh exchange; 1) a DCN signal was
received from the destination unit, and the line was cut; or 2) a DIS (NSF, CSI) signal was received from the
destination unit and, in response to the signal, the unit transmitted a DCN signal, and the line was cut.
Description
Description
1-4-96
2RG/2RH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Copystar cs 3511i

Table of Contents