Code
Contents
3310
CIS AGC error
One of the gains is FF during
the CCD lamp AGC is being
processed.
3500
Communication error
between scanner and ASIC
A wrong read-back value.
Scanner sequence error
3600
3800
AFE error
When writing the data, read
and write data does not match
3 times in succession.
Related parts
CIS
DPSHD PWB
Replace the DPSHD PWB.
Engine PWB
Main PWB
Replace the main PWB (see page 1-5-54).
Engine PWB
Engine PWB
CCD PWB
Replace the ISU and execute U411 (see
page 1-5-34,1-3-130).
1-4-29
Check procedures/
corrective measures
1. Execute U906 Separating Operation
Release (see page 1-3-191).
2. To check the lamp, execute U061 CIS
(see page 1-3-43).
3. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
DP CIS and DPSHD PWB (YC2)
DPSHD PWB (YC3) and DP relay PWB
(YC2)
4. If the wiring is disconnected, shorted or
grounded, replace the wiring.
5. Replace the CIS and execute U091 and
U411 (see page 1-3-58,1-3-130).
1. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
Engine PWB (YC3) and Main PWB
(YC64)
2. If the wiring is disconnected, shorted or
grounded, replace the wiring.
3. Replace the Engine PWB and execute
U411 (see page 1-5-59,1-3-130).
1. Execute U021 memory initializing (see
page 1-3-28).
2. Replace the Engine PWB and execute
U411 (see page 1-5-59,1-3-130).
1. Confirm that the FCC wiring connector is
not distorted and connect the FCC
wiring all the way in.
CCD PWB (YC1) and Engine PWB
(YC29)
2. If the FCC wiring is disconnected,
replace the FCC wiring.
3. Replace the Engine PWB and execute
U411 (see page 1-3-130).
2RG/2RH