Kyocera Copystar CS 3011i Service Manual page 144

Table of Contents

Advertisement

Setting: B/W Level1
1.Select the item to set.
2.By using the [+] [-] keys or the numeric keys, change the setting value.
Items
Original1
Original2
Original3
*: Lowering the setting value improves the sensor's sensitivity and high density originals can be detected
but the original mat may be detected as an original.
*: If differentiating each setting value, mis-detection may appear depending on the condition of placing
the original.
Original mat
1
2
297 mm
3.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
*: The screen for selecting a maintenance item No. is displayed.
Contents
Sets the threshold to judge the original
Sets the threshold to judge the original
Sets the threshold to judge the original
Fig.
1
2
3
3
Figure 3-16
1-3-61
Setting range
0 to 255
0 to 255
0 to 255
Original
Original width size range
R/G/B
1
A4R to A3
8.5" to 11"
2
B6R to A4R
5.5" to 8.5"
3
to B6R
2RG/2RH
Initial
setting
50
1
50
1
50
1
to 5.5"
Data
varia-
tion