U158
Developer counter
(Message: Developing Unit Counter)
Contents
Displays the developer counter
Purpose
Execute to check the developer unit usage status.
Method
1.Press the [Start] key.
*: The developer count is displayed.
K
Completion
Press the [Stop] key.
*: The screen for selecting a maintenance item No. is displayed.
U161
Fuser temperature adjustment
(Message: Adjust Fuser Control Temperature)
Contents
Set the fuser control temperature, control temperature correction, other setting value.
Purpose
Normally no need to change. However, change the setting as corrective measures for paper curl, creases
and fusing failure on thick paper.
Method
1.Press the [Start] key.
2.Select the item to set.
3.By using the [+] [-] keys or the numeric keys, change the setting value.
T1
T2
T3
T4
T5
T6
T9
TA
4.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
*: The screen for selecting a maintenance item No. is displayed.
Items
Displaying the developer counts
Items
T1 setting
T2 setting
T3 setting
T4 setting
T5 setting
T6 setting
T9 setting
TA setting
Contents
Contents
1-3-74
2RG/2RH
Setting range
Initial setting
120 to 185
110
120 to 185
1 to 65
130 to 220
180
130 to 220
190
1 to 99
1
1 to 99
1
140 to 200
165
50 to 150
100